Results of Elaborating the Demo Model of a Small Turboshaft Gas Turbine Engine and a Power Unit on Its Basis

Instruments and Experimental Techniques · Springer Nature · 2026-10-01 · DOI: 10.1134/S0040601526700436

Аннотация

Abstract The article presents the results of elaborating a compact small gas turbine power unit relating to the 180 kW capacity class intended for a wide use in various industry branches. The design solutions for and technical characteristics of modern compact power units in the considered class are reviewed and analyzed, based on which a rational configuration of the power unit developed has been shaped. Its design features and advantages reached in implementing the proposed solutions are given. The computation study results were obtained with the use of computer simulation techniques and include the performance indicators of the compressor, turbine, combustor, and the gas generator’s rotor supports lubrication and cooling system. After carrying out design optimization, the compressor and turbine adiabatic efficiency values amounted to no less than 83 and 91%, respectively, and the combustor efficiency in the power unit design operation modes was no less than 96%. The design calculations of the bearing supports lubrication and cooling system show that to ensure their sufficient cooling, it is necessary to decrease the temperature of compressed air extracted from the compressor by no less than 100°С. The article presents the data of the rotor unit experimental studies, within the framework of which the effectiveness of an open-loop air–oil lubrication and cooling system of the rotor supports is confirmed, and the minimal oil flowrate sufficient for lubricating the bearings in the operation modes studied is determined. In the course of experimental studies of the fuel system equipped with a motor driven pump, its serviceability is confirmed, and the fuel flowrate nonuniformity through the centrifugal nozzles installed on the fuel manifold is estimated. It is shown that in the case of using single-channel nozzles, the fuel flowrate nonuniformity may reach 48% in various modes, whereas the nozzle with fuel bypass ensures the flowrate nonuniformity equal to 3‒7%, a circumstance that should be taken into account in designing the combustor. In the gas generator tests, the mismatch between the data on design operation modes obtained experimentally and by using the mathematical simulation method was less than 5%. A demo model of the developed compact power unit relating to the 180 kW capacity class has been produced.

Читать у издателя →

Похожие статьи