Comparison of Cochlear Implant Hearing Outcomes Following Manual and Robotic Electrode Insertion

Ilana Yellin, Nathan M. Jacob, Michael D. Seidman, ArielMae Brownlee
Otolaryngology - Head and Neck Surgery · Wiley · 2026-11-16 · DOI: 10.1002/ohn.70522

Abstract

Abstract Objective The purpose of this study is to compare initial low frequency hearing preservation (LFHP) in patients undergoing robotic‐assisted cochlear implantation (CI) to those undergoing manual CI. Study Design Retrospective review. Setting Tertiary referral center. Methods Adult CI patients with low‐frequency residual hearing, defined as a preoperative low‐frequency pure tone average (LFPTA) at 250 and 500 Hz ≤80 dB HL, were included in this study. Patients underwent either robotic‐assisted or manual CI. All implants utilized lateral wall electrodes. The primary outcomes were the change in LFPTA (ΔLFPTA) and the presence of LFHP, defined as ΔLFPTA ≤ 30 dB HL, following robotic‐assisted or manual CI. Results 35 robotic‐assisted and 27 manual cases met the inclusion criteria for comparison of initial LFHP. The mean preoperative LFPTA was 56.14 and 62.04 dB HL ( P = .11) while the mean postoperative LFPTA was 88.86 and 91.02 dB HL for robotic‐assisted and manual insertion, respectively ( P = .63). The ΔLFPTA was not significantly different between the robotic‐assisted and manual insertion groups (32.17 dB HL robotic‐assisted vs 28.98 dB HL manual, P = .82). LFHP was similar between groups (57.10% robotic‐assisted vs 51.90% manual, P = .68). Conclusion There is no significant difference in initial LFHP between robotic‐assisted and manual CI in this study group, though robotic‐assisted insertion may still offer benefit for preservation of residual hearing over time. Further studies with longer follow‐up are needed to fully evaluate the impact of robotic‐assisted insertion on hearing preservation.

Read at publisher →

Similar articles