ABSTRACT Although arachnoid cysts, particularly large cysts in the posterior fossa, are rare in preterm infants, early diagnosis using advanced imaging techniques is essential. We describe the case of a preterm infant born at 30 + 6 weeks gestation, presenting with respiratory distress and requiring resuscitation. Prenatal ultrasonography revealed lateral ventricular dilation and a posterior fossa cyst. Postnatal cranial ultrasonography and magnetic resonance imaging confirmed the presence of a large arachnoid cyst, which was conservatively managed. This case highlights the utility of prenatal/postnatal imaging for identifying arachnoid cysts and the importance of early diagnosis and management. Conservative management is effective in asymptomatic patients.
Yan Yan, Meihan Liu. A Large Arachnoid Cyst in a Preterm Infant: A Case Report and Management Insights. // Journal of Clinical Ultrasound. – 2026. – DOI: 10.1002/jcu.70437. – URL: https://onlinelibrary.wiley.com/doi/10.1002/jcu.70437?af=R
Yan Yan & Meihan Liu (2026). A Large Arachnoid Cyst in a Preterm Infant: A Case Report and Management Insights. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.70437
Yan Yan and Meihan Liu. “A Large Arachnoid Cyst in a Preterm Infant: A Case Report and Management Insights.” Journal of Clinical Ultrasound, 2026. doi:10.1002/jcu.70437.
@article{Yan2026,
title = {A Large Arachnoid Cyst in a Preterm Infant: A Case Report and Management Insights},
author = {Yan, Yan and Liu, Meihan},
journal = {Journal of Clinical Ultrasound},
year = {2026},
doi = {10.1002/jcu.70437},
url = {https://onlinelibrary.wiley.com/doi/10.1002/jcu.70437?af=R}
}
Purpose To develop a fast, general‐purpose framework for voxelwise noise characterization in iterative MRI reconstructions, recovering the image‐domain noise variance, the primary quantity from which SNR, ‐factor, and related...
ABSTRACT Purpose To develop a computationally viable autofocus method for estimating 3D rigid motion in MR imaging. Theory and Methods The proposed method, REACT, assumes a piecewise‐constant motion trajectory and estimates the rigid...
ABSTRACT Purpose To improve magnetic resonance fingerprinting (MRF) T 2 encoding by combining phase‐based T 2 encoding with optimal experiment design. Methods Six hundred–timepoint MRF sequences with jointly optimized flip angle (FA)...
ABSTRACT Innominate artery stenosis is an uncommon but clinically significant cause of cerebrovascular insufficiency with complex and often underrecognized hemodynamic manifestations. We present two cases highlighting the diagnostic...