BMC Gastroenterology Gastroenterology

Comparison of different techniques of endoscopic submucosal dissection for colorectal lesions: a systematic review and network meta-analysis of randomized controlled trials

Yang, Yichao, Kou, Jingwei, Wang, Kaiyue, Zhang, Dongxuan, Xiong, Ying
Springer Nature · 2026-11-23 · DOI 10.1186/s12876-026-05601-y

Abstract

Background Endoscopic submucosal dissection (ESD) is widely recognized as the standard minimally invasive approach for the resection of superficial colorectal neoplasms. Although several modified ESD techniques have been developed, their comparative effectiveness and safety remain uncertain. This network meta-analysis (NMA) was conducted to systematically evaluate and compare the efficacy and safety of different ESD techniques. Methods PubMed, Embase, Web of Science, and the Cochrane Library were searched from inception to 1 May 2026 for randomized controlled trials comparing colorectal ESD techniques. Outcomes were en bloc resection, R0 resection, procedure time, dissection speed and adverse events. A frequentist random-effects network meta-analysis was fitted, with the between-study variance estimated by restricted maximum likelihood. Effects were expressed as risk ratios (RR) or mean differences (MD) with 95% confidence intervals (CI). The protocol was registered in PROSPERO (CRD420261404995). Results Fourteen trials with 1,351 patients were included. The network was centred on conventional ESD (C-ESD): apart from one direct pocket-creation method ESD (PCM-ESD) versus pocket-traction-assisted ESD (PTA-ESD) comparison, every comparison between two modified techniques passed through C-ESD, and no closed loop existed, so inconsistency could not be tested. No modified technique differed from C-ESD in en bloc resection, R0 resection or adverse events; every 95% CI included the null, and two estimates rest on one trial each. Traction-assisted ESD (TA-ESD) shortened procedure time [MD -16.63, 95% CI (-24.32, -8.94)], and the difference persisted after exclusion of the two trials that violated transitivity [MD -21.11, 95% CI (-30.91, -11.32)]. Hybrid ESD (H-ESD), underwater ESD (UW-ESD) and saline-pocket ESD (SPCM-ESD) dissected faster than C-ESD [MD 6.90, 95% CI (2.95, 10.86); 3.42 (0.41, 6.44); 4.40 (1.57, 7.23)]. SUCRA values ranged from 0.081 to 0.890 and changed direction between outcomes; they are descriptive only. Conclusions In 14 trials with 1,351 patients, no modified technique differed from conventional ESD in en bloc resection, R0 resection or adverse events, so none can be recommended over it on efficacy or safety grounds. Traction-assisted ESD shortened the procedure by 16.6 min (95% CI -24.32, -8.94), and the difference held at -21.11 min (95% CI -30.91, -11.32) after the two trials that violated transitivity were excluded. Hybrid, underwater and saline-pocket ESD dissected faster, but on two trials or fewer, and whether a 17-minute saving is clinically meaningful remains open: no trial was powered for perforation or delayed bleeding.

Read at publisher →