Canadian Journal of Chemical Engineering Химическая технология (общая)

Influences of liquid viscosities on the critical diameter of drop coalescence on a liquid–liquid interface

Lang Pan, Xiong Yu
Wiley · 2026-11-17 · DOI 10.1002/cjce.70649

Аннотация

Abstract A drop generally does not completely merge on a liquid–liquid interface, but partially coalesces leaving a small daughter drop, known as partial coalescence in separation engineering. The present work adopted an interface capturing model to investigate coalescence of drops on a liquid–liquid interface. For most liquid–liquid pairs, it is identified that there is a critical diameter D * below which only complete coalescence is observed. The critical diameter D * is found to be a function of the ambient liquid viscosity and the drop liquid viscosity. With increase of the ambient liquid viscosity μ c , the critical diameter D * also increases. It follows that the viscous effect of the ambient liquid on hindering partial coalescence might be counteracted by increasing the drop diameter. However, as the drop liquid viscosity μ d increases, the critical diameter D * first decreases and then increases. This is because the drop liquid viscosity μ d not only influences the horizontal contraction of the liquid neck, but also affects the vertical liquid drainage. A liquid neck contraction and expansion model is adopted to explain these phenomena, which is helpful to understand mechanisms of partial coalescence. Finally, a correlation was proposed to predict the critical diameter D * with relative errors less than 10%.

Читать у издателя →