ABSTRACT Chrysotile asbestos was detected at controlled concentrations in the work environment. When a truck‐etched membrane filter was used as the substrate, the chrysotile detection limit was 0.15 μg. To achieve analysis at the control concentration level (0.15 f mL −1 ≧ 1.7 × 10 −6 μg L −1 ) in the work environment, approximately 180,000 L of air must be collected on a 25‐mm‐diameter track‐etched membrane filter. This analysis is practically difficult considering the collection time required. Using a tungsten plate, the detection limit for chrysotile was 30 ng, which was one‐tenth the chrysotile detection limit of the track‐etched membrane filter. Furthermore, experiments in which chrysotile was detached from the membrane filter showed a recovery rate of over 40% on the tungsten plate. Combining these results, chrysotile detection at the management concentration level was possible through X‐ray diffraction after collecting ~45,000 L of air (10 L min −1 for 75 min) on the filter.
Atsushi Ohbuchi, Atsushi Iguchi, Yuya Koike, Toshihiro Nakamura. High‐Sensitivity Analysis of Chrysotile Asbestos Collected From the Working Environment on a Metal Plate Using a Desktop X‐Ray Diffractometer. // X-Ray Spectrometry. – 2026. – DOI: 10.1002/xrs.70126. – URL: https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/xrs.70126?af=R
Atsushi Ohbuchi, Atsushi Iguchi, Yuya Koike, & Toshihiro Nakamura (2026). High‐Sensitivity Analysis of Chrysotile Asbestos Collected From the Working Environment on a Metal Plate Using a Desktop X‐Ray Diffractometer. X-Ray Spectrometry. https://doi.org/10.1002/xrs.70126
Atsushi Ohbuchi, et al. “High‐Sensitivity Analysis of Chrysotile Asbestos Collected From the Working Environment on a Metal Plate Using a Desktop X‐Ray Diffractometer.” X-Ray Spectrometry, 2026. doi:10.1002/xrs.70126.
@article{Ohbuchi2026,
title = {High‐Sensitivity Analysis of Chrysotile Asbestos Collected From the Working Environment on a Metal Plate Using a Desktop X‐Ray Diffractometer},
author = {Ohbuchi, Atsushi and Iguchi, Atsushi and Koike, Yuya and Nakamura, Toshihiro},
journal = {X-Ray Spectrometry},
year = {2026},
doi = {10.1002/xrs.70126},
url = {https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/xrs.70126?af=R}
}
ABSTRACT The alumina produced via the Bayer process inevitably introduces LiF impurities into the aluminum electrolyte and reacts with AlF 3 forming Al‐F complexes. For comprehensive understanding of the microstructural properties of...
ABSTRACT Myeloid leukaemia (ML) is a myeloproliferative disorder, characterised by the over‐proliferation of myeloid cells within the bone marrow, which mostly occurs in adults over age 50 years and results in higher mortality. Early...
ABSTRACT Raman thermometry is widely used to determine thermal‐transport properties from atomically thin membranes to active device regions. Raman‐active phonon modes change predictably with temperature, enabling a focused laser to act...