Computational Thermal Analysis of Waveform Dependent Ozone Generation in an Encased Coaxial-Cylindrical DBD Reactor
Аннотация
The aim of the study was to develop an indirect calibration methodology to quantify the gas temperature in an encased dielectric barrier discharge (DBD) reactor using a two-stage coupled thermal–fluid simulation in COMSOL Multiphysics. Sinusoidal and sub-microsecond pulsed waveforms were compared at 7 and 8.5 kV. The conductivity of the plasma region ( σ plasma ) was calibrated from the experimentally measured power consumption ( P exp ) to determine the volumetric heat source ( Q avg,vol ), which was used to calculate the simulated power consumption P sim . The calibration yielded a P sim – P exp error within 0.5% for all waveform conditions. At 8.5 kV, the pulsed condition consumed about one-third of the power of the sinusoidal condition, which reduced Q avg,vol and the temperature rise (Δ T ). At comparable Δ T values of 5 and 6 K, the pulsed condition produced about 13 times the ozone concentration of the sinusoidal condition. The σ plasma -inversion methodology quantified the bulk gas temperature in the encased coaxial-cylindrical DBD reactor and demonstrated that the maximum gas temperature remained below the threshold of ozone thermal decomposition. Therefore, the σ plasma -inversion methodology is well suited for evaluating the gas temperature within encased DBD reactors and offers an alternative to conventional optical temperature diagnostics.