Ecological Solutions and Evidence Management, Monitoring, Policy and Law

How to reduce avian electrocutions: Insulation or structural changes of dangerous poles

Virginia Morandini, Jose Rafael Garrido, Miguel Ferrer
Wiley · 2026-10-01 · DOI 10.1002/2688-8319.70273

Abstract

Abstract Electrocutions of birds in power lines, particularly in distribution power lines, have been a well‐known and widespread global conservation problem since the 1970s. Electrocutions of Spanish Imperial Eagles ( Aquila adalberti ) have been particularly well documented, with incidents reported from all over Spain, Portugal and even Morocco, representing a major cause of mortality capable of extinguishing local populations. In Spain, mitigation measures aimed at ameliorating the impact of power lines, particularly for the Spanish Imperial Eagles, were implemented starting in 1991. In one of the most used temporary settlement areas during juvenile dispersal of young eagles, retrofitting was carried out on 613 of 823 pylons (74.48%) that were classified as dangerous in 1991. During the next 20 years, only one juvenile Spanish Imperial Eagle was found electrocuted in this area, but in the period 2011–2013, five eagles were found to be electrocuted. We try to elucidate why this high mortality rate reappears after 20 years and how we can predict and avoid this recurrent problem in eagle conservation. The mean cost of the insulation of dangerous poles was 984 $ per intervened pole. An alternative modification, like structural changes in the design of the top of the poles, has a cost of around 4700 $ per pole and can last up to 60 years. The insulation of dangerous poles was 79% cheaper than the structural design changes of the top of the poles, but according to our results, 10.7% of the insulated poles would deteriorate 20 years later and 26.1% suffered poor maintenance. Taken together, if we want to obtain the same result than with structural changes in the design of the top of the poles, whose life is around 60 years, we have to invest 603,192 $ once to start and 129,888 $ every 20 years, still cheaper than alternative modification. Structural changes in the design of the top of the poles in the same 613 poles would cost 2,881,100 $; insulation strategy would be 65.53% cheaper, achieving the same results. Solution : The cost‐effective results of insulation of dangerous poles were clearly favourable to insolation as a better strategy than the structural design changes.

Read at publisher →