Accurate and continuous electrocardiogram (ECG) parameter measurement outside hospital environments is essential for real-time cardiac health monitoring and telemedicine, yet comprehensive validation of on-device computational methods across heterogeneous real-world populations remains limited. We conducted a real-world validation using two datasets: HeartVoice-ECG-lite (369 participants with single-lead ECG recordings annotated by two cardiologists) and PTB-XL/PTB-XL+ (21,354 patients with 12-lead ECG recordings and diagnostic annotations). FeatureDB ( https://github.com/PKUDigitalHealth/FeatureDB ) was applied to compute PR, QT, and QTc intervals from single-lead signals. Accuracy was assessed using mean absolute error (MAE), correlation, and Bland-Altman analysis. Diagnostic performance for first-degree atrioventricular block (AVBI, based on PR) and long QT syndrome (LQT, based on QTc) was benchmarked against commercial 12-lead systems (12SL, Uni-G) and an open-source algorithm (Deli) using AUC, accuracy, sensitivity, and specificity. FeatureDB-derived parameters showed high concordance with annotations, with MAEs comparable to inter-observer variability and Pearson correlations ranging from 0.836 to 0.960. For AVBI detection, FeatureDB achieved an AUC of 0.787; for LQT, an AUC of 0.684. These results indicate that FeatureDB enables accurate real-time on-device ECG parameter computation suitable for scalable telemedicine, decentralized screening, and continuous community monitoring.
Fan, Sumei, Zhang, Deyun, Wang, Yue et al. Multicenter real world validation of on device single lead ECG parameters for remote cardiac assessment. // npj Cardiovascular Health. – 2026. – DOI: 10.1038/s44325-026-00145-2. – URL: https://www.nature.com/articles/s44325-026-00145-2
Fan, Sumei, Zhang, Deyun, Wang, Yue, Geng, Shijia, Lu, Kun, Sang, Meng, Xu, Weilun, Wang, Haixue, Zhao, Qinghao, Cheng, Chuandong, Wang, Peng, Hong, & Shenda (2026). Multicenter real world validation of on device single lead ECG parameters for remote cardiac assessment. npj Cardiovascular Health. https://doi.org/10.1038/s44325-026-00145-2
Fan, et al. “Multicenter real world validation of on device single lead ECG parameters for remote cardiac assessment.” npj Cardiovascular Health, 2026. doi:10.1038/s44325-026-00145-2.
@article{Fan2026,
title = {Multicenter real world validation of on device single lead ECG parameters for remote cardiac assessment},
author = {Fan and Sumei and Zhang and Deyun and Wang and Yue and Geng and Shijia and Lu and Kun and Sang and Meng and Xu and Weilun and Wang and Haixue and Zhao and Qinghao and Cheng and Chuandong and Wang and Peng and Hong and Shenda},
journal = {npj Cardiovascular Health},
year = {2026},
doi = {10.1038/s44325-026-00145-2},
url = {https://www.nature.com/articles/s44325-026-00145-2}
}
Fibroblast growth factor 21 (FGF21) is a key regulator in metabolic diseases. Serum FGF21 levels are significantly elevated in patients with hyperuricemia and correlate positively with uric acid. In hyperuricemic mice, FGF21 is...
Artificial intelligence (AI) in cardiology is rapidly expanding, but enthusiasm for anticipated benefits should be balanced by a more critical inspection of ethical concerns. In this state-of-the-art review, we discuss the four pillars...
Acute stroke alerts are frequently activated for non-cerebrovascular conditions, creating false positives that strain resources and increase diagnostic uncertainty. We developed machine learning models integrating large-language models,...
Circadian imbalance may contribute to hypertension, but its association with incident hypertension, genetic susceptibility, and molecular pathways remains unclear. This prospective study included 107,270 UK Biobank participants free of...