A CWHO-STU optimized FOPID-based coordinated control strategy for enhanced power management and voltage regulation in hybrid AC/DC microgrids

Journal of Computational Electronics · Springer Nature · 2026-10-26 · DOI: 10.1007/s12667-026-00836-w

Аннотация

The increasing complexity and demand for efficient power management in MGs require efficient integration between AC and DC subgrids for improved power transfer and voltage quality. To address this, this work developed a unique coordinated control method for an MG with energy resources and hybrid AC/DC loads. A Model Predictive Power and Voltage Control (MPPVC) method for DC/AC interlinking converters was initially proposed as a coordinated control strategy that would produce higher-quality voltages and make sure enhanced power transfer between AC and DC subgrids. The main aim of this work is to propose a fine-tuned Fractional-order Proportional Integral Derivative (FOPID) controller to improve the control structure of the Energy Storage System (ESS). To further optimize the FOPID controller’s performance, a novel hybrid STWHO optimization algorithm is proposed, which integrates the exploration capability of the Sooty Tern Optimization Algorithm (STOA) with the exploitation strength of Wild Horse Optimization (WHO). Unlike conventional hybrid approaches, the proposed Customized Wild Horse Optimization with Sooty Tern Updation (CWHO-STU) introduces a modified position update mechanism in which the WHO search dynamics are adaptively guided by STOA-inspired spiral foraging behavior, which enables improved convergence speed and avoidance of local minima. The proposed method proposed a technique in terms of measurements of load voltage as well as grid voltage and performed better than alternative current models. In terms of rise time, the proposed Customized Wild Horse Optimization with Sooty Tern Updation (CWHO-STU) model overcomes the established MPPVC, Firefly Algorithm (FF), Index-based Fly and Rider combined Model (IF-RM), Rider Optimization Algorithm (ROA), STOA, and WHO models by 9.04%, 1355.2%, 8.12%, 96.89%, 4.94%, and 97.38%, respectively. Similarly, the settling time of the proposed model outperforms the traditional MPPVC, FF, IF-RM, ROA, STOA, and WHO models by 32.33%, 74.01%, 0.73%, 2.03%, 65.46%, and 52.85%. Overall, the results demonstrated that the proposed STWHO-based approach was effective and suitable for enhancing power management and voltage stability in hybrid AC/DC microgrids.

Читать у издателя →

Похожие статьи