The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series (N10‐N150)
Matheus Rebello do Nascimento,
Josilene Cerqueria Santos,
Eric Matos Macedo,
Leonardo de Castro Pacífico,
Luís Alexandre Gonçalves Magalhães X-Ray Spectrometry
· Wiley
· 2026-05-25
· DOI: 10.1002/xrs.70119
Аннотация
ABSTRACT Spectrometry is an important tool for the characterization of X‐ray beams in ionizing radiation metrology. However, the use of solid‐state spectrometers for accurate measurements requires correction of spectral distortions caused by the interaction between photons and the detector. In this sense, the Stripping methodology was used to correct these distortions and validate the method for the ISO 4037‐1 narrow spectra series, from qualities N10 to N150, measured with an Amptek CdTe spectrometer. This method was implemented in Python 3, and its performance was evaluated quantitatively through the ISO mean energy and spectral resolution requirements, and qualitatively through the spectral shape. Monte Carlo simulations of the pulse‐height distribution were performed for the N120 and N150 spectra using EGSnrc to investigate the influence of the manufacturer's collimator on the measurements. It was observed that the differences between the quantitative parameters of the corrected spectra are within the standard tolerance, except for N120 and N150, for which the shape, mean energy, and spectral resolution are significantly different, with errors of 5% and 9%, and 11% and 22%, respectively. These results suggest that the Stripping method reduces spectral distortion and is therefore suitable for correcting N10–N100 radiation qualities with a CdTe spectrometer. The divergences found for N120 and N150 are therefore related to the manufacturer's collimator, since its thickness does not properly shield these beams. New studies should therefore be conducted to develop an improved design, as suggested by the simulations.
Matheus Rebello do Nascimento, Josilene Cerqueria Santos, Eric Matos Macedo, Leonardo de Castro Pacífico, Luís Alexandre Gonçalves Magalhães. The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series (N10‐N150). // X-Ray Spectrometry. – 2026. – DOI: 10.1002/xrs.70119. – URL: https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/xrs.70119?af=R
Matheus Rebello do Nascimento, Josilene Cerqueria Santos, Eric Matos Macedo, Leonardo de Castro Pacífico, & Luís Alexandre Gonçalves Magalhães (2026). The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series (N10‐N150). X-Ray Spectrometry. https://doi.org/10.1002/xrs.70119
Matheus Rebello do Nascimento, et al. “The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series (N10‐N150).” X-Ray Spectrometry, 2026. doi:10.1002/xrs.70119.
@article{Nascimento2026,
title = {The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series (N10‐N150)},
author = {Nascimento, Matheus Rebello do and Santos, Josilene Cerqueria and Macedo, Eric Matos and Pacífico, Leonardo de Castro and Magalhães, Luís Alexandre Gonçalves},
journal = {X-Ray Spectrometry},
year = {2026},
doi = {10.1002/xrs.70119},
url = {https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/xrs.70119?af=R}
}
ABSTRACT The alumina produced via the Bayer process inevitably introduces LiF impurities into the aluminum electrolyte and reacts with AlF 3 forming Al‐F complexes. For comprehensive understanding of the microstructural properties of...
ABSTRACT Myeloid leukaemia (ML) is a myeloproliferative disorder, characterised by the over‐proliferation of myeloid cells within the bone marrow, which mostly occurs in adults over age 50 years and results in higher mortality. Early...
ABSTRACT Raman thermometry is widely used to determine thermal‐transport properties from atomically thin membranes to active device regions. Raman‐active phonon modes change predictably with temperature, enabling a focused laser to act...