Structural Design of Tall and Special Buildings Строительство

Numerical Simulation of Flow Field and Wind Pressure on Ultra‐High Hyperbolic Steel Cooling Towers Under Varying Porosity Conditions

Wang Jianshuo, Zhang Jinheng, Zhang Kun, Chen Zhihua, Wei Tao, Wang Guipu
Wiley · 2026-09-01 · DOI 10.1002/tal.70173

Аннотация

ABSTRACT Cooling towers are highly sensitive to wind loads. Variations in bottom porosity give rise to complex flow field and wind pressure characteristics, and existing codes show insufficient applicability. Taking a 21‐story hyperbolic steel cooling tower of approximately 210 m as the research object, this paper studies computational domain dimensions, flow field characteristics and wind load distribution under different porosities. The results indicate that computational domain parameters do not change the basic flow field morphology but affect the amplitude and distribution range of wind pressure in the side‐wind and flow‐around regions. As porosity rises from 0% to 100%, airflow inside and outside the tower changes from separated to interconnected, forming stable upward flow inside the tower at 50% porosity. The shape coefficient in the side‐wind region under 0% porosity differs most notably, with an absolute difference of 0.27 at the throat height from the 50% porosity case, and the maximum absolute negative pressure is about 1.14 times the minimum. Porosity variations affect surface wind pressure, with diverse changes in pressure extreme positions and differences on each meridian, and the maximum pressure difference reaches 0.82.

Читать у издателя →